Subscribe to our newsletter

FLIR FC-324R

Fixed Network Thermal Cameras
MODEL: FLIR FC-324R

Description

The FC-Series R features on-board, non-contact temperature measurement capabilities for fire detection, safety, and thermal monitoring of substations, waste disposal, and valuable equipment. FC-Series R combines state-of-the-art image detail and on-board video analytics to provide reliable detection. Flexible alarming options include email, web and mobile apps, edge image storage, digital outputs, or VMS event notifications.

Additional information

Array Format (NTSC)

320 × 240

Detector Type

Long-Life, Uncooled VOx Microbolometer

Dimensions (L x W x H)

233.68 × 116.84 × 104.14 mm (9.2 × 4.6 × 4.1 in) w/o sun shield; 274.32 × 137.16 × 111.76 mm (10.8 × 5.4 × 4.4 in) w/ sun shield

Effective Resolution

76, 800

Focus Range

Athermalized, focus-free

Weight

18 kg (4.0 lb) w/o sun shield, 2.2 kg (4.8 lb) w/sun shield

Zoom

Continuous E-zoom, up to 4X

Composite Video NTSC or PAL

Yes; Hybrid system with IP & Analog video

Ethernet

Yes

External Analytics Compatible

Yes

Network APIs

Nexus SDK for comprehensive system control and integration, Nexus CGI for http command interfaces ONVIF Profile S

Video Over Ethernet

Two independent channels of H.264, MPEG-4 & M-JPEG (see website for full details)

Humidity

0-95% relative

IP Rating

IP66 & IP67

Operating Temperature Range

-50°C to 70°C (continuous operation) -40°C to 70°C (cold start)

Shock

MIL-STD-810F "Transportation"

Storage Temperature Range

-55°C to 85°C

Vibe

IEC 60068-2-27

Field of View

24° × 19° (FC-324R; 19 mm)

Image Uniformity Optimization

Automatic Flat Field Correction (FFC) Thermal and Temporal Triggers

Spectral Range

7.5 µm to 13.5 µm

Streaming Resolution

D1: 720 × 576, 4CIF: 704 × 576, Native: 640 × 512, Q-Native: 320 × 256, CIF: 352 × 288, QCIF: 176 × 144

Thermal AGC Modes

Auto AGC, Manual AGC, Plateau Equalization AGC, Linear AGC, Auto Dynamic Detail Enhancement (DDE), Max Gain Setting

Thermal AGC Region of Interest

Default, Presets and User definable to insure optimal image quality on subjects of interest

Measurement Accuracy

(+/-)5°C or 5% of reading

Measurement Range

-10°C to 110°C

Input Voltage

11-44 VDC (no lens heaters), 16-44 VDC (w/lens heaters), 14-32 VAC (no lens heaters), 16-32 VAC (w/lens heaters), PoE (IEEE 802.3af-2003), PoE+ (IEEE 802.3at-2009)

Power Consumption

24 VDC 5 W nominal, 21 W peak (w/heaters), 24 VAC, 8 VA nominal, 29 VA peak (w/heaters), Approvals, FCC Part15, Subpart B, Class B, CE: EN 55022 Class B

Surge Immunity on AC Power Lines

EN 55024: 2010 and 55022: 2010 to 4.0kV on AC aux power lines

Surge Immunity on Signal Lines

EN 55024: 2010 and 55022: 2010 to 4.0kV